Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as the theory of "quality the basic, have confidence in the very first and management the advanced" for Liquid Flow Measurement, Clamp On Ultrasonic Flow Meter, In Line Air Flow Meter, Our business has been devoting that "customer first" and committed to helping shoppers expand their small business, so that they become the Big Boss !
Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2700 Multi-loop digital display controller – Sinomeasure Detail:

  • Specification
 Product Multi-loop digital display controller
 Model SUP-2700
 Dimension A. 160*80*136mm
B. 80*160*136mm
C. 96*96*136mm
Measurement accuracy ±0.2%FS
Transmission output Analog output—-4-20mA、1-5v、
0-10mA、0-5V、0-20mA、0-10V
Alarm Output Over-range display value flashing alarm function

With upper and lower limit alarm function, with alarm return difference setting;Relay capacity:
AC220V/2A(big)DC24V/2A(big)(Resistive load)
Note: When the load exceeds the relay contact capacity, please do not directly carry the load

Power supply AC/DC100~240V (Frequency 50/60Hz)  Power consumption≤5W
DC 20~29V  Power consumption≤3W
Use environment Operating temperature(-10~50℃)No condensation, no icing
Printout RS232 printing interface, micro-matched printer can realize manual, timing and alarm printing functions

 

  • Introduction

Multi-loop digital display control instrument with automatic SMD packaging technology, has a strong anti-jamming capability. It can be used in conjunction with various sensors、transmitters to display temperature, pressure, liquid level, speed, force and other physical parameters, and it can measure 8~16 loops input go the rounds, support 8~16 loops “uniform alarm output”, “16 loops separate alarm output”, “uniform transition output ”, “8 loops separate transition output” and 485/232 communication, and is applicable in system with various measuring points.

Input signal type list:

Graduation Number Pn Signal type Measure range Graduation Number Pn Signal type Measure range
0 TC B 400~1800℃ 18 Remote Resistance 0~350Ω -1999~9999
1 TC S 0~1600℃ 19 Remote Resistance 3 0~350Ω -1999~9999
2 TC K 0~1300℃ 20 0~20mV -1999~9999
3 TC E 0~1000℃ 21 0~40mV -1999~9999
4 TC T -200.0~400.0℃ 22 0~100mV -1999~9999
5 TC J 0~1200℃ 23 -20~20mV -1999~9999
6 TC R 0~1600℃ 24 -100~100mV -1999~9999
7 TC N 0~1300℃ 25 0~20mA -1999~9999
8 F2 700~2000℃ 26 0~10mA -1999~9999
9 TC Wre3-25 0~2300℃ 27 4~20mA -1999~9999
10 TC Wre5-26 0~2300℃ 28 0~5V -1999~9999
11 RTD  Cu50 -50.0~150.0℃ 29 1~5V -1999~9999
12 RTD  Cu53 -50.0~150.0℃ 30 -5~5V -1999~9999
13 RTD  Cu100 -50.0~150.0℃ 31 0~10V -1999~9999
14 RTD  Pt100 -200.0~650.0℃ 32 0~10mA square -1999~9999
15 RTD  BA1 -200.0~600.0℃ 33 4~20mA square -1999~9999
16 RTD  BA2 -200.0~600.0℃ 34 0~5V square -1999~9999
17 Linear resistance 0~400Ω -1999~9999 35 1~5V square -1999~9999

Product detail pictures:

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2700 Multi-loop digital display controller – Sinomeasure detail pictures

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2700 Multi-loop digital display controller – Sinomeasure detail pictures

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2700 Multi-loop digital display controller – Sinomeasure detail pictures

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2700 Multi-loop digital display controller – Sinomeasure detail pictures

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2700 Multi-loop digital display controller – Sinomeasure detail pictures


Related Product Guide:

The corporation upholds the philosophy of "Be No.1 in high quality, be rooted on credit rating and trustworthiness for growth", will continue to serve outdated and new consumers from home and overseas whole-heatedly for Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2700 Multi-loop digital display controller – Sinomeasure , The product will supply to all over the world, such as: Lebanon, Islamabad, Guinea, We insist on the principle of "Credit being primary, Customers being the king and Quality being the best", we are looking forward to the mutual cooperation with all friends at home and abroad and we will create a bright future of business.
  • As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Elsa from Auckland - 2018.12.14 15:26
    We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Amelia from Switzerland - 2018.10.09 19:07