Reliable good quality and very good credit standing are our principles, which will help us at a top-ranking position. Adhering to your tenet of "quality 1st, purchaser supreme" for Gas Flow Meter, Flow Instruments, Irrigation Flow Meter, For further information, please do not hesitate to contact us. All inquiries from you will be highly appreciated.
Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2100 Single-loop digital display controller – Sinomeasure Detail:

  • Specification
 Product Single-loop digital display controller
 Model SUP-2100
 Dimension A. 160*80*110mm
B. 80*160*110mm
C. 96*96*110mm
D. 96*48*110mm
E. 48*96*110mm
F.72*72*110mm
H. 48*48*110mm
K.160*80*110mm
L. 80*160*110mm
M. 96*96*110mm
Measurement accuracy ±0.2%FS
Transmission output Analog output—-4-20mA、1-5v、
0-10mA、0-5V、0-20mA、0-10V
Alarm Output ALM—-With upper and lower limit alarm function, with alarm return difference setting;Relay capacity:
AC125V/0.5A(small)DC24V/0.5A(small)(Resistive load)
AC220V/2A(big)DC24V/2A(big)(Resistive load)
Note: When the load exceeds the relay contact capacity, please do not directly carry the load
Power supply AC/DC100~240V (Frequency 50/60Hz)  Power consumption≤5W
DC 12~36V  Power consumption≤3W
Use environment Operating temperature(-10~50℃)No condensation, no icing
Printout RS232 printing interface, micro-matched printer can realize manual, timing and alarm printing functions

 

  • Introduction

Single-loop digital display controller with automatic SMD packaging technology, has a strong anti-jamming capability. Designed with dual-screen LED display, it could display more contents. It  can be used in conjunction with various sensors、transmitters to display temperature, pressure, liquid level, speed, force and other physical parameters, and to output alarm control, analog transmission, RS-485/232 communication etc. More than the traditional digital display meters is a new function to restore the factory default parameters, with easier operation and better applicability.

Input signal type list:

Graduation Number Pn Signal type Measure range Graduation Number Pn Signal type Measure range
0 TC B 400~1800℃ 18 Remote Resistance 0~350Ω -1999~9999
1 TC S 0~1600℃ 19 Remote Resistance 3 0~350Ω -1999~9999
2 TC K 0~1300℃ 20 0~20mV -1999~9999
3 TC E 0~1000℃ 21 0~40mV -1999~9999
4 TC T -200.0~400.0℃ 22 0~100mV -1999~9999
5 TC J 0~1200℃ 23 -20~20mV -1999~9999
6 TC R 0~1600℃ 24 -100~100mV -1999~9999
7 TC N 0~1300℃ 25 0~20mA -1999~9999
8 F2 700~2000℃ 26 0~10mA -1999~9999
9 TC Wre3-25 0~2300℃ 27 4~20mA -1999~9999
10 TC Wre5-26 0~2300℃ 28 0~5V -1999~9999
11 RTD  Cu50 -50.0~150.0℃ 29 1~5V -1999~9999
12 RTD  Cu53 -50.0~150.0℃ 30 -5~5V -1999~9999
13 RTD  Cu100 -50.0~150.0℃ 31 0~10V -1999~9999
14 RTD  Pt100 -200.0~650.0℃ 32 0~10mA square -1999~9999
15 RTD  BA1 -200.0~600.0℃ 33 4~20mA square -1999~9999
16 RTD  BA2 -200.0~600.0℃ 34 0~5V square -1999~9999
17 Linear resistance 0~400Ω -1999~9999 35 1~5V square -1999~9999

Product detail pictures:

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures

Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures


Related Product Guide:

Fast and great quotations, informed advisers to help you choose the correct solution that suits all your requirements, a short creation time, responsible top quality manage and distinct providers for paying and shipping affairs for Wholesale Dealers of Polarographic Oxygen Analyzer - SUP-2100 Single-loop digital display controller – Sinomeasure , The product will supply to all over the world, such as: Madrid, Jordan, Mauritius, Our products are very popular in the word, like South American, Africa, Asia and so on. Companies to "create first-class products" as the goal, and strive to provide customers with high quality products, provide high-quality after-sales service and technical support, and customer mutual benefit, create a better career and future!
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Clementine from Seattle - 2017.08.21 14:13
    We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
    5 Stars By Mavis from Poland - 2018.07.12 12:19