head_banner

Water Ph Controller Supplier – Sinomeasure Multi-parameter analyzer – Sinomeasure

Water Ph Controller Supplier – Sinomeasure Multi-parameter analyzer – Sinomeasure

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Trustworthy good quality and excellent credit score standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality first, buyer supreme" for Inline Ph Sensor, Turbidity Meter Online, Water Tank Sensor, Please sense no cost to speak to us anytime. We are going to reply you when we receive your inquiries. Remember to note that samples are available before we start our business enterprise.
Water Ph Controller Supplier – Sinomeasure Multi-parameter analyzer – Sinomeasure Detail:

Item Index Value
System working power (220±22)V AC,(50±1)Hz
Power 30W
Cabinet size 800mm*506mm*180mm (standard version)
Weight about 15Kg
Storage temperature 4℃~+50℃
Working temperature 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module)
Working humidity ≤95%RH (no condensation)
Inlet flow 500~1000 mL/min
Inlet pressure < 3kg/cm³
Communication interface RS485 Modbus RTU communication protocol + wireless interface
Turbidity Range 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU
Resolution 0.001NTU
Lower detection limit 0.02NTU;0.1NTU(0-4000NTU)
Zero drift ≤1.5%
Indication stability ≤1.5%
Accuracy 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU)
Repeatability ≤3%
Response time ≤60s
Recommended maintenance period 3-12 months (depending on the water quality on site)
Residual chlorine/chlorine dioxide Range 0-5mg/L / 0-20mg/L
Resolution 0.01mg/L
Lower detection limit 0.05mg/L
Accuracy ±0.05mg/L or ±5% (DPD comparison error ±10%)
Response time ≤120 seconds
Recommended maintenance period 1-3 months or weekly calibration, 3-6 months to replace consumables
PH /ORP(optional) Range 0-14pH, ±2000mV(ORP)
Resolution 0.01pH, ±1mV(ORP)
Accuracy ±0.1pH, ±20mV(ORP)or ±2%
Repeatability ±0.1pH, ±10mV(ORP)
Response time ≤60 seconds
Recommended maintenance period 1-3 months
Temperature Range -20℃ – 85℃
Resolution 0.1℃
Accuracy ±0.5℃
Repeatability ≤0.5℃
Response time ≤25 seconds
Recommended maintenance period 12 months
Conductivity (Optional) Range 1-2000uS/cm / 1~200mS/m
Accuracy ±1.5%FS
Repeatability ≤0.5%FS
Response time ≤30 seconds
Recommended maintenance period 3-6 months
Dissolved oxygen (Optional) Range 0-20mg/L
Accuracy ±0.3mg/L
Repeatability ≤±1.5%
Response time ≤30 seconds
Recommended maintenance period 1-3 months
Expansion port Port type RS485、4-20mA、0-5V
Item Index Value
System working power (220±22)V AC,(50±1)Hz
Power 30W
Cabinet size 800mm*506mm*180mm (standard version)
Weight about 15Kg
Storage temperature 4℃~+50℃
Working temperature 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module)
Working humidity ≤95%RH (no condensation)
Inlet flow 500~1000 mL/min
Inlet pressure < 3kg/cm³
Communication interface RS485 Modbus RTU communication protocol + wireless interface
Turbidity Range 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU
Resolution 0.001NTU
Lower detection limit 0.02NTU;0.1NTU(0-4000NTU)
Zero drift ≤1.5%
Indication stability ≤1.5%
Accuracy 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU)
Repeatability ≤3%
Response time ≤60s
Recommended maintenance period 3-12 months (depending on the water quality on site)
Residual chlorine/chlorine dioxide Range 0-5mg/L / 0-20mg/L
Resolution 0.01mg/L
Lower detection limit 0.05mg/L
Accuracy ±0.05mg/L or ±5% (DPD comparison error ±10%)
Response time ≤120 seconds
Recommended maintenance period 1-3 months or weekly calibration, 3-6 months to replace consumables
PH /ORP(optional) Range 0-14pH, ±2000mV(ORP)
Resolution 0.01pH, ±1mV(ORP)
Accuracy ±0.1pH, ±20mV(ORP)or ±2%
Repeatability ±0.1pH, ±10mV(ORP)
Response time ≤60 seconds
Recommended maintenance period 1-3 months
Temperature Range -20℃ – 85℃
Resolution 0.1℃
Accuracy ±0.5℃
Repeatability ≤0.5℃
Response time ≤25 seconds
Recommended maintenance period 12 months
Conductivity (Optional) Range 1-2000uS/cm / 1~200mS/m
Accuracy ±1.5%FS
Repeatability ≤0.5%FS
Response time ≤30 seconds
Recommended maintenance period 3-6 months
Dissolved oxygen (Optional) Range 0-20mg/L
Accuracy ±0.3mg/L
Repeatability ≤±1.5%
Response time ≤30 seconds
Recommended maintenance period 1-3 months
Expansion port Port type RS485、4-20mA、0-5V

 

  • Introduction

The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.


Product detail pictures:

Water Ph Controller Supplier –  Sinomeasure Multi-parameter analyzer – Sinomeasure detail pictures

Water Ph Controller Supplier –  Sinomeasure Multi-parameter analyzer – Sinomeasure detail pictures

Water Ph Controller Supplier –  Sinomeasure Multi-parameter analyzer – Sinomeasure detail pictures


Related Product Guide:

The consumer fulfillment is our primary goal. We uphold a consistent level of professionalism, top quality, credibility and service for Water Ph Controller Supplier – Sinomeasure Multi-parameter analyzer – Sinomeasure , The product will supply to all over the world, such as: Vancouver, Argentina, Paris, We have top engineers in these industries and an efficient team in the research. What is more, now we have our own archives mouths and markets in China at low cost. Therefore, we can meet different inquiries from different clients. Remember to find our website to check more information from our merchandise.
  • In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
    5 Stars By Andrew from Ghana - 2018.07.12 12:19
    Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Beulah from Zurich - 2018.11.02 11:11