| Item | Index | Value |
| System | working power | (220±22)V AC,(50±1)Hz |
| Power | 30W | |
| Cabinet size | 800mm*506mm*180mm (standard version) | |
| Weight | about 15Kg | |
| Storage temperature | 4℃~+50℃ | |
| Working temperature | 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module) | |
| Working humidity | ≤95%RH (no condensation) | |
| Inlet flow | 500~1000 mL/min | |
| Inlet pressure | < 3kg/cm³ | |
| Communication interface | RS485 Modbus RTU communication protocol + wireless interface | |
| Turbidity | Range | 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU |
| Resolution | 0.001NTU | |
| Lower detection limit | 0.02NTU;0.1NTU(0-4000NTU) | |
| Zero drift | ≤1.5% | |
| Indication stability | ≤1.5% | |
| Accuracy | 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU) | |
| Repeatability | ≤3% | |
| Response time | ≤60s | |
| Recommended maintenance period | 3-12 months (depending on the water quality on site) | |
| Residual chlorine/chlorine dioxide | Range | 0-5mg/L / 0-20mg/L |
| Resolution | 0.01mg/L | |
| Lower detection limit | 0.05mg/L | |
| Accuracy | ±0.05mg/L or ±5% (DPD comparison error ±10%) | |
| Response time | ≤120 seconds | |
| Recommended maintenance period | 1-3 months or weekly calibration, 3-6 months to replace consumables | |
| PH /ORP(optional) | Range | 0-14pH, ±2000mV(ORP) |
| Resolution | 0.01pH, ±1mV(ORP) | |
| Accuracy | ±0.1pH, ±20mV(ORP)or ±2% | |
| Repeatability | ±0.1pH, ±10mV(ORP) | |
| Response time | ≤60 seconds | |
| Recommended maintenance period | 1-3 months | |
| Temperature | Range | -20℃ – 85℃ |
| Resolution | 0.1℃ | |
| Accuracy | ±0.5℃ | |
| Repeatability | ≤0.5℃ | |
| Response time | ≤25 seconds | |
| Recommended maintenance period | 12 months | |
| Conductivity (Optional) | Range | 1-2000uS/cm / 1~200mS/m |
| Accuracy | ±1.5%FS | |
| Repeatability | ≤0.5%FS | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 3-6 months | |
| Dissolved oxygen (Optional) | Range | 0-20mg/L |
| Accuracy | ±0.3mg/L | |
| Repeatability | ≤±1.5% | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 1-3 months | |
| Expansion port | Port type | RS485、4-20mA、0-5V |
| Item | Index | Value |
| System | working power | (220±22)V AC,(50±1)Hz |
| Power | 30W | |
| Cabinet size | 800mm*506mm*180mm (standard version) | |
| Weight | about 15Kg | |
| Storage temperature | 4℃~+50℃ | |
| Working temperature | 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module) | |
| Working humidity | ≤95%RH (no condensation) | |
| Inlet flow | 500~1000 mL/min | |
| Inlet pressure | < 3kg/cm³ | |
| Communication interface | RS485 Modbus RTU communication protocol + wireless interface | |
| Turbidity | Range | 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU |
| Resolution | 0.001NTU | |
| Lower detection limit | 0.02NTU;0.1NTU(0-4000NTU) | |
| Zero drift | ≤1.5% | |
| Indication stability | ≤1.5% | |
| Accuracy | 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU) | |
| Repeatability | ≤3% | |
| Response time | ≤60s | |
| Recommended maintenance period | 3-12 months (depending on the water quality on site) | |
| Residual chlorine/chlorine dioxide | Range | 0-5mg/L / 0-20mg/L |
| Resolution | 0.01mg/L | |
| Lower detection limit | 0.05mg/L | |
| Accuracy | ±0.05mg/L or ±5% (DPD comparison error ±10%) | |
| Response time | ≤120 seconds | |
| Recommended maintenance period | 1-3 months or weekly calibration, 3-6 months to replace consumables | |
| PH /ORP(optional) | Range | 0-14pH, ±2000mV(ORP) |
| Resolution | 0.01pH, ±1mV(ORP) | |
| Accuracy | ±0.1pH, ±20mV(ORP)or ±2% | |
| Repeatability | ±0.1pH, ±10mV(ORP) | |
| Response time | ≤60 seconds | |
| Recommended maintenance period | 1-3 months | |
| Temperature | Range | -20℃ – 85℃ |
| Resolution | 0.1℃ | |
| Accuracy | ±0.5℃ | |
| Repeatability | ≤0.5℃ | |
| Response time | ≤25 seconds | |
| Recommended maintenance period | 12 months | |
| Conductivity (Optional) | Range | 1-2000uS/cm / 1~200mS/m |
| Accuracy | ±1.5%FS | |
| Repeatability | ≤0.5%FS | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 3-6 months | |
| Dissolved oxygen (Optional) | Range | 0-20mg/L |
| Accuracy | ±0.3mg/L | |
| Repeatability | ≤±1.5% | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 1-3 months | |
| Expansion port | Port type | RS485、4-20mA、0-5V |
-
Introduction
The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.

Product detail pictures:
Related Product Guide:
Adhering into the principle of "quality, provider, performance and growth", we now have gained trusts and praises from domestic and intercontinental consumer for Professional China Magnetic Water Flow Sensor - Sinomeasure Multi-parameter analyzer – Sinomeasure , The product will supply to all over the world, such as: Puerto Rico, azerbaijan, Marseille, All of our products comply with international quality standards and are greatly appreciated in a variety of markets around the world. If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients in the near future.
Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.