Professional China Magnetic Water Flow Sensor - Sinomeasure Multi-parameter analyzer – Sinomeasure
Professional China Magnetic Water Flow Sensor - Sinomeasure Multi-parameter analyzer – Sinomeasure Detail:
| Item | Index | Value |
| System | working power | (220±22)V AC,(50±1)Hz |
| Power | 30W | |
| Cabinet size | 800mm*506mm*180mm (standard version) | |
| Weight | about 15Kg | |
| Storage temperature | 4℃~+50℃ | |
| Working temperature | 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module) | |
| Working humidity | ≤95%RH (no condensation) | |
| Inlet flow | 500~1000 mL/min | |
| Inlet pressure | < 3kg/cm³ | |
| Communication interface | RS485 Modbus RTU communication protocol + wireless interface | |
| Turbidity | Range | 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU |
| Resolution | 0.001NTU | |
| Lower detection limit | 0.02NTU;0.1NTU(0-4000NTU) | |
| Zero drift | ≤1.5% | |
| Indication stability | ≤1.5% | |
| Accuracy | 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU) | |
| Repeatability | ≤3% | |
| Response time | ≤60s | |
| Recommended maintenance period | 3-12 months (depending on the water quality on site) | |
| Residual chlorine/chlorine dioxide | Range | 0-5mg/L / 0-20mg/L |
| Resolution | 0.01mg/L | |
| Lower detection limit | 0.05mg/L | |
| Accuracy | ±0.05mg/L or ±5% (DPD comparison error ±10%) | |
| Response time | ≤120 seconds | |
| Recommended maintenance period | 1-3 months or weekly calibration, 3-6 months to replace consumables | |
| PH /ORP(optional) | Range | 0-14pH, ±2000mV(ORP) |
| Resolution | 0.01pH, ±1mV(ORP) | |
| Accuracy | ±0.1pH, ±20mV(ORP)or ±2% | |
| Repeatability | ±0.1pH, ±10mV(ORP) | |
| Response time | ≤60 seconds | |
| Recommended maintenance period | 1-3 months | |
| Temperature | Range | -20℃ – 85℃ |
| Resolution | 0.1℃ | |
| Accuracy | ±0.5℃ | |
| Repeatability | ≤0.5℃ | |
| Response time | ≤25 seconds | |
| Recommended maintenance period | 12 months | |
| Conductivity (Optional) | Range | 1-2000uS/cm / 1~200mS/m |
| Accuracy | ±1.5%FS | |
| Repeatability | ≤0.5%FS | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 3-6 months | |
| Dissolved oxygen (Optional) | Range | 0-20mg/L |
| Accuracy | ±0.3mg/L | |
| Repeatability | ≤±1.5% | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 1-3 months | |
| Expansion port | Port type | RS485、4-20mA、0-5V |
| Item | Index | Value |
| System | working power | (220±22)V AC,(50±1)Hz |
| Power | 30W | |
| Cabinet size | 800mm*506mm*180mm (standard version) | |
| Weight | about 15Kg | |
| Storage temperature | 4℃~+50℃ | |
| Working temperature | 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module) | |
| Working humidity | ≤95%RH (no condensation) | |
| Inlet flow | 500~1000 mL/min | |
| Inlet pressure | < 3kg/cm³ | |
| Communication interface | RS485 Modbus RTU communication protocol + wireless interface | |
| Turbidity | Range | 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU |
| Resolution | 0.001NTU | |
| Lower detection limit | 0.02NTU;0.1NTU(0-4000NTU) | |
| Zero drift | ≤1.5% | |
| Indication stability | ≤1.5% | |
| Accuracy | 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU) | |
| Repeatability | ≤3% | |
| Response time | ≤60s | |
| Recommended maintenance period | 3-12 months (depending on the water quality on site) | |
| Residual chlorine/chlorine dioxide | Range | 0-5mg/L / 0-20mg/L |
| Resolution | 0.01mg/L | |
| Lower detection limit | 0.05mg/L | |
| Accuracy | ±0.05mg/L or ±5% (DPD comparison error ±10%) | |
| Response time | ≤120 seconds | |
| Recommended maintenance period | 1-3 months or weekly calibration, 3-6 months to replace consumables | |
| PH /ORP(optional) | Range | 0-14pH, ±2000mV(ORP) |
| Resolution | 0.01pH, ±1mV(ORP) | |
| Accuracy | ±0.1pH, ±20mV(ORP)or ±2% | |
| Repeatability | ±0.1pH, ±10mV(ORP) | |
| Response time | ≤60 seconds | |
| Recommended maintenance period | 1-3 months | |
| Temperature | Range | -20℃ – 85℃ |
| Resolution | 0.1℃ | |
| Accuracy | ±0.5℃ | |
| Repeatability | ≤0.5℃ | |
| Response time | ≤25 seconds | |
| Recommended maintenance period | 12 months | |
| Conductivity (Optional) | Range | 1-2000uS/cm / 1~200mS/m |
| Accuracy | ±1.5%FS | |
| Repeatability | ≤0.5%FS | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 3-6 months | |
| Dissolved oxygen (Optional) | Range | 0-20mg/L |
| Accuracy | ±0.3mg/L | |
| Repeatability | ≤±1.5% | |
| Response time | ≤30 seconds | |
| Recommended maintenance period | 1-3 months | |
| Expansion port | Port type | RS485、4-20mA、0-5V |
-
Introduction
The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.

Product detail pictures:
Related Product Guide:
We thinks what clients think, the urgency of urgency to act from the interests of a purchaser position of principle, allowing for greater top quality, decrease processing costs, price ranges are much more reasonable, won the new and aged prospects the support and affirmation for Professional China Magnetic Water Flow Sensor - Sinomeasure Multi-parameter analyzer – Sinomeasure , The product will supply to all over the world, such as: Bulgaria, Australia, Greek, We always insist on the principle of "Quality and service are the life of the product". Till now, our products have been exported to more than 20 countries under our strict quality control and high level service.
Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.