Our well-equipped facilities and excellent excellent management throughout all stages of creation enables us to guarantee total buyer satisfaction for In Line Water Flow Meter, In Line Water Flow Meter, Signal Converter, We are keeping durable business relationships with more than 200 wholesalers in the USA, the UK, Germany and Canada. If you are interested in any of our products, please feel free to contact us.
Online Ph Sensor Factory – Sinomeasure Multi-parameter analyzer – Sinomeasure Detail:

Item Index Value
System working power (220±22)V AC,(50±1)Hz
Power 30W
Cabinet size 800mm*506mm*180mm (standard version)
Weight about 15Kg
Storage temperature 4℃~+50℃
Working temperature 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module)
Working humidity ≤95%RH (no condensation)
Inlet flow 500~1000 mL/min
Inlet pressure < 3kg/cm³
Communication interface RS485 Modbus RTU communication protocol + wireless interface
Turbidity Range 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU
Resolution 0.001NTU
Lower detection limit 0.02NTU;0.1NTU(0-4000NTU)
Zero drift ≤1.5%
Indication stability ≤1.5%
Accuracy 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU)
Repeatability ≤3%
Response time ≤60s
Recommended maintenance period 3-12 months (depending on the water quality on site)
Residual chlorine/chlorine dioxide Range 0-5mg/L / 0-20mg/L
Resolution 0.01mg/L
Lower detection limit 0.05mg/L
Accuracy ±0.05mg/L or ±5% (DPD comparison error ±10%)
Response time ≤120 seconds
Recommended maintenance period 1-3 months or weekly calibration, 3-6 months to replace consumables
PH /ORP(optional) Range 0-14pH, ±2000mV(ORP)
Resolution 0.01pH, ±1mV(ORP)
Accuracy ±0.1pH, ±20mV(ORP)or ±2%
Repeatability ±0.1pH, ±10mV(ORP)
Response time ≤60 seconds
Recommended maintenance period 1-3 months
Temperature Range -20℃ – 85℃
Resolution 0.1℃
Accuracy ±0.5℃
Repeatability ≤0.5℃
Response time ≤25 seconds
Recommended maintenance period 12 months
Conductivity (Optional) Range 1-2000uS/cm / 1~200mS/m
Accuracy ±1.5%FS
Repeatability ≤0.5%FS
Response time ≤30 seconds
Recommended maintenance period 3-6 months
Dissolved oxygen (Optional) Range 0-20mg/L
Accuracy ±0.3mg/L
Repeatability ≤±1.5%
Response time ≤30 seconds
Recommended maintenance period 1-3 months
Expansion port Port type RS485、4-20mA、0-5V
Item Index Value
System working power (220±22)V AC,(50±1)Hz
Power 30W
Cabinet size 800mm*506mm*180mm (standard version)
Weight about 15Kg
Storage temperature 4℃~+50℃
Working temperature 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module)
Working humidity ≤95%RH (no condensation)
Inlet flow 500~1000 mL/min
Inlet pressure < 3kg/cm³
Communication interface RS485 Modbus RTU communication protocol + wireless interface
Turbidity Range 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU
Resolution 0.001NTU
Lower detection limit 0.02NTU;0.1NTU(0-4000NTU)
Zero drift ≤1.5%
Indication stability ≤1.5%
Accuracy 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU)
Repeatability ≤3%
Response time ≤60s
Recommended maintenance period 3-12 months (depending on the water quality on site)
Residual chlorine/chlorine dioxide Range 0-5mg/L / 0-20mg/L
Resolution 0.01mg/L
Lower detection limit 0.05mg/L
Accuracy ±0.05mg/L or ±5% (DPD comparison error ±10%)
Response time ≤120 seconds
Recommended maintenance period 1-3 months or weekly calibration, 3-6 months to replace consumables
PH /ORP(optional) Range 0-14pH, ±2000mV(ORP)
Resolution 0.01pH, ±1mV(ORP)
Accuracy ±0.1pH, ±20mV(ORP)or ±2%
Repeatability ±0.1pH, ±10mV(ORP)
Response time ≤60 seconds
Recommended maintenance period 1-3 months
Temperature Range -20℃ – 85℃
Resolution 0.1℃
Accuracy ±0.5℃
Repeatability ≤0.5℃
Response time ≤25 seconds
Recommended maintenance period 12 months
Conductivity (Optional) Range 1-2000uS/cm / 1~200mS/m
Accuracy ±1.5%FS
Repeatability ≤0.5%FS
Response time ≤30 seconds
Recommended maintenance period 3-6 months
Dissolved oxygen (Optional) Range 0-20mg/L
Accuracy ±0.3mg/L
Repeatability ≤±1.5%
Response time ≤30 seconds
Recommended maintenance period 1-3 months
Expansion port Port type RS485、4-20mA、0-5V

 

  • Introduction

The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.


Product detail pictures:

Online Ph Sensor Factory –  Sinomeasure Multi-parameter analyzer – Sinomeasure detail pictures

Online Ph Sensor Factory –  Sinomeasure Multi-parameter analyzer – Sinomeasure detail pictures

Online Ph Sensor Factory –  Sinomeasure Multi-parameter analyzer – Sinomeasure detail pictures


Related Product Guide:

As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for Online Ph Sensor Factory – Sinomeasure Multi-parameter analyzer – Sinomeasure , The product will supply to all over the world, such as: Ottawa, Swedish, Slovak Republic, Our company sticks to the principle of "high quality, reasonable price and timely delivery". We sincerely hope to establish good cooperative relationships with our new and old business partners from all parts of the world. We hope to work with you and serve you with our excellent goods and services. Welcome to join us!
  • The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Lena from Guyana - 2017.08.15 12:36
    The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Patricia from Vancouver - 2017.10.27 12:12