Measuring principle
A fluid flowing with a certain velocity and passing a fixed obstruction generates vortices. The generation of vortices is known as Karman’s Vortices.The frequency of vortex shedding is a direct linear function of fluid velocity and frequency depends upon the shape and face width of bluff body. Since the width of obstruction and inner diameter of the pipe will be more or less constant, the frequency is given by the expression:
f=(St*V)/c*D -
Installation
Wafer connection: DN15-DN300(priority PN2.5MPa)
-
Accuracy
1.5%, 1.0%
-
Range Ratio
Gas density:1.2kg/m3, Range ratio: 8:1
-
Medium Temperature
-20°C ~ +150°C、-20°C ~ +260°C、-20°C ~ +300°C
-
Power Supply
24VDC±5%
Li battery(3.6VDC)
-
Output signal
4-20mA
Frequency
RS485 communication (Modbus RTU)
-
Ingress protection
IP65
-
Body Materials
Stainless stell
-
Display
128*64 dot matrix LCD
Noted: the product strictly prohibited to be used in explosion-proof occasions.
Product detail pictures:
Related Product Guide:
Every single member from our large efficiency revenue team values customers' wants and company communication for One of Hottest for Pipe Flow Meter - SUP-LUGB Vortex flowmeter wafer installation – Sinomeasure , The product will supply to all over the world, such as: Ghana, Malawi, Kuala Lumpur, During the development, our company has built a well-known brand. It is well highly acclaimed by our customers. OEM and ODM are accepted. We are looking forward to customers from all over the world to join us to a wild cooperation.