Our organization sticks to your principle of "Quality may be the life of your organization, and reputation will be the soul of it" for Liquid Level Sensor, Clamp On Flow Meter, Conductivity Controller Cooling Tower, We Sincerely welcome clients from all around the entire world to visit us, with our multifaceted cooperation and get the job done with each other to develop new markets, build win-win outstanding future.
New Fashion Design for Online Dissolved Oxygen Meter - SUP-602S Intelligent signal isolator for voltage/current – Sinomeasure Detail:

  • Advantages

• Dielectric strength (leakage current 1mA, with test time of 1 minute):

≥1500VAC (among input/output/power supply)

• Insulation resistance:

≥100MΩ (among input/output/power supply)

• EMC: EMC conforms to IEC61326-3

• Power supply: DC 18~32V (typical value 24V DC)

• Full-load power:

Single-channel input, single-channel output    0.6W

Single-channel input, double-channel output   1.5W

 

  • Specification

• Allowed input signal:

DC: 0(4)mA~20mA;0mA~10mA

Other signal types may be customized as required, see the product label for details;

• Input impedance: about 100Ω

• Allowed output signal:

• Current: 0(4)mA~20mA;0mA~10mA

Voltage: 0(1) V~5V;0V~10V

Other signal types may be customized as required, see the product label for the specific signal types;

• Output load capacity:

0(4)mA~20mA:≤550Ω;0mA~10mA:≤1.1kΩ

0(1)V~5V:≥1MΩ; 0V~10V:≥2MΩ

Other load demands may be customized as required, see the product label for details.

• Distribution output voltage:

No-load voltage≤26V, full-load voltage≥23V

Accuracy of isolated transmission:

±0.1%F∙S(25℃±2℃)

• Temperature drift: 40ppm/℃

• Response time: ≤0.5s


Product detail pictures:

New Fashion Design for Online Dissolved Oxygen Meter - SUP-602S Intelligent signal isolator for voltage/current – Sinomeasure detail pictures

New Fashion Design for Online Dissolved Oxygen Meter - SUP-602S Intelligent signal isolator for voltage/current – Sinomeasure detail pictures

New Fashion Design for Online Dissolved Oxygen Meter - SUP-602S Intelligent signal isolator for voltage/current – Sinomeasure detail pictures


Related Product Guide:

abide by the contract", conforms into the market requirement, joins in the market competition by its good quality also as provides a lot more comprehensive and great company for purchasers to let them turn into huge winner. The pursue from the firm, would be the clients' gratification for New Fashion Design for Online Dissolved Oxygen Meter - SUP-602S Intelligent signal isolator for voltage/current – Sinomeasure , The product will supply to all over the world, such as: Comoros, Oman, Iran, By adhering to the principle of "human oriented, winning by quality", our company sincerely welcomes merchants from at home and abroad to visit us, talk business with us and jointly create a brilliant future.
  • The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By Margaret from Ukraine - 2018.09.23 18:44
    The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Julie from Lebanon - 2018.06.12 16:22