Good User Reputation for In Line Air Flow Meter - SUP-LUGB Vortex flowmeter wafer installation – Sinomeasure
Good User Reputation for In Line Air Flow Meter - SUP-LUGB Vortex flowmeter wafer installation – Sinomeasure Detail:
-
Measuring principle
A fluid flowing with a certain velocity and passing a fixed obstruction generates vortices. The generation of vortices is known as Karman’s Vortices.The frequency of vortex shedding is a direct linear function of fluid velocity and frequency depends upon the shape and face width of bluff body. Since the width of obstruction and inner diameter of the pipe will be more or less constant, the frequency is given by the expression:
f=(St*V)/c*D -
Installation
Wafer connection: DN15-DN300(priority PN2.5MPa)
-
Accuracy
1.5%, 1.0%
-
Range Ratio
Gas density:1.2kg/m3, Range ratio: 8:1
-
Medium Temperature
-20°C ~ +150°C、-20°C ~ +260°C、-20°C ~ +300°C
-
Power Supply
24VDC±5%
Li battery(3.6VDC)
-
Output signal
4-20mA
Frequency
RS485 communication (Modbus RTU)
-
Ingress protection
IP65
-
Body Materials
Stainless stell
-
Display
128*64 dot matrix LCD
Noted: the product strictly prohibited to be used in explosion-proof occasions.
Product detail pictures:
Related Product Guide:
We take pleasure in an exceptionally excellent status between our buyers for our superb merchandise good quality, aggressive price tag and the greatest support for Good User Reputation for In Line Air Flow Meter - SUP-LUGB Vortex flowmeter wafer installation – Sinomeasure , The product will supply to all over the world, such as: Comoros, Gabon, Norwegian, During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !