head_banner

Good Quality Magnetic Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure

Good Quality Magnetic Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

We can easily normally satisfy our respected buyers with our excellent high-quality, excellent selling price and good service due to we've been far more expert and more hard-working and do it in cost-effective way for Turbine Flow Meter, Magnetic Type Flow Meter, 2 Inch Flow Meter, Any interest, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
Good Quality Magnetic Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure Detail:

  • Measuring principle

    A fluid flowing with a certain velocity and passing a fixed obstruction generates vortices. The generation of vortices is known as Karman’s Vortices.The frequency of vortex shedding is a direct linear function of fluid velocity and frequency depends upon the shape and face width of bluff body.

Since the width of obstruction and inner diameter of the pipe will be more or less constant, the frequency is given by the expression:

f=StV/d

In the formula:
f – Karman vortex frequency generated at one side of bluff body (Hz)
St – strouhal number (non-dimensional number)
V – average speed of fluid (m/s)
d – width of bluff body (m)

  • Installation

    Wafer connection: DN15-DN300(priority PN2.5MPa)

    Flange connection: DN15-DN50(priority PN2.5MPa)

DN65-DN200(priority PN1.6MPa)

DN250-DN300(priority PN1.0MPa)

  • Accuracy

Gas without compensation: DN15-DN25–1.5%, DN32-DN200–1.0%, DN250-DN300–1.5%

  • Range Ratio

Gas density:1.2kg/m3, Range ratio: 8:1

  • Medium Temperature

-20°C ~ +150°C、-20°C ~ +260°C、-20°C ~ +300°C

  • Power Supply

24VDC±5%

Li battery(3.6VDC)

  • Output signal

4-20mA

Frequency

RS485 communication (Modbus RTU)

  • Ingress protection

IP65

  • Body Materials

    Stainless stell

  • Display

    128*64 dot matrix LCD

 

Noted: the product strictly prohibited to be used in explosion-proof occasions.

 


Product detail pictures:

Good Quality Magnetic Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure detail pictures

Good Quality Magnetic Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure detail pictures

Good Quality Magnetic Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure detail pictures

Good Quality Magnetic Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure detail pictures

Good Quality Magnetic Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure detail pictures


Related Product Guide:

Gaining client pleasure is our company's aim without end. We are going to make excellent efforts to create new and top-quality goods, meet your special requirements and provide you with pre-sale, on-sale and after-sale companies for Good Quality Magnetic Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure , The product will supply to all over the world, such as: Switzerland, Cyprus, Turkey, Company name, is always regarding quality as company' s foundation, seeking for development via high degree of credibility , abiding by ISO quality management standard strictly, creating top-ranking company by spirit of progress-marking honesty and optimism.
  • Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Anne from Czech - 2017.04.18 16:45
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By ron gravatt from Chile - 2018.11.28 16:25