head_banner

Buy Ph Controler Suppliers – Sinomeasure Multi-parameter analyzer – Sinomeasure

Buy Ph Controler Suppliers – Sinomeasure Multi-parameter analyzer – Sinomeasure

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

We can easily normally satisfy our respected buyers with our excellent high-quality, excellent selling price and good service due to we've been far more expert and more hard-working and do it in cost-effective way for Digital Water Flow Meter Manufacturers, Level Transmitter, Wastewater Level Sensor, As we're moving forward, we continue to keep an eye on our ever-expanding merchandise range and make improvement to our services.
Buy Ph Controler Suppliers – Sinomeasure Multi-parameter analyzer – Sinomeasure Detail:

Item Index Value
System working power (220±22)V AC,(50±1)Hz
Power 30W
Cabinet size 800mm*506mm*180mm (standard version)
Weight about 15Kg
Storage temperature 4℃~+50℃
Working temperature 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module)
Working humidity ≤95%RH (no condensation)
Inlet flow 500~1000 mL/min
Inlet pressure < 3kg/cm³
Communication interface RS485 Modbus RTU communication protocol + wireless interface
Turbidity Range 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU
Resolution 0.001NTU
Lower detection limit 0.02NTU;0.1NTU(0-4000NTU)
Zero drift ≤1.5%
Indication stability ≤1.5%
Accuracy 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU)
Repeatability ≤3%
Response time ≤60s
Recommended maintenance period 3-12 months (depending on the water quality on site)
Residual chlorine/chlorine dioxide Range 0-5mg/L / 0-20mg/L
Resolution 0.01mg/L
Lower detection limit 0.05mg/L
Accuracy ±0.05mg/L or ±5% (DPD comparison error ±10%)
Response time ≤120 seconds
Recommended maintenance period 1-3 months or weekly calibration, 3-6 months to replace consumables
PH /ORP(optional) Range 0-14pH, ±2000mV(ORP)
Resolution 0.01pH, ±1mV(ORP)
Accuracy ±0.1pH, ±20mV(ORP)or ±2%
Repeatability ±0.1pH, ±10mV(ORP)
Response time ≤60 seconds
Recommended maintenance period 1-3 months
Temperature Range -20℃ – 85℃
Resolution 0.1℃
Accuracy ±0.5℃
Repeatability ≤0.5℃
Response time ≤25 seconds
Recommended maintenance period 12 months
Conductivity (Optional) Range 1-2000uS/cm / 1~200mS/m
Accuracy ±1.5%FS
Repeatability ≤0.5%FS
Response time ≤30 seconds
Recommended maintenance period 3-6 months
Dissolved oxygen (Optional) Range 0-20mg/L
Accuracy ±0.3mg/L
Repeatability ≤±1.5%
Response time ≤30 seconds
Recommended maintenance period 1-3 months
Expansion port Port type RS485、4-20mA、0-5V
Item Index Value
System working power (220±22)V AC,(50±1)Hz
Power 30W
Cabinet size 800mm*506mm*180mm (standard version)
Weight about 15Kg
Storage temperature 4℃~+50℃
Working temperature 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module)
Working humidity ≤95%RH (no condensation)
Inlet flow 500~1000 mL/min
Inlet pressure < 3kg/cm³
Communication interface RS485 Modbus RTU communication protocol + wireless interface
Turbidity Range 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU
Resolution 0.001NTU
Lower detection limit 0.02NTU;0.1NTU(0-4000NTU)
Zero drift ≤1.5%
Indication stability ≤1.5%
Accuracy 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU)
Repeatability ≤3%
Response time ≤60s
Recommended maintenance period 3-12 months (depending on the water quality on site)
Residual chlorine/chlorine dioxide Range 0-5mg/L / 0-20mg/L
Resolution 0.01mg/L
Lower detection limit 0.05mg/L
Accuracy ±0.05mg/L or ±5% (DPD comparison error ±10%)
Response time ≤120 seconds
Recommended maintenance period 1-3 months or weekly calibration, 3-6 months to replace consumables
PH /ORP(optional) Range 0-14pH, ±2000mV(ORP)
Resolution 0.01pH, ±1mV(ORP)
Accuracy ±0.1pH, ±20mV(ORP)or ±2%
Repeatability ±0.1pH, ±10mV(ORP)
Response time ≤60 seconds
Recommended maintenance period 1-3 months
Temperature Range -20℃ – 85℃
Resolution 0.1℃
Accuracy ±0.5℃
Repeatability ≤0.5℃
Response time ≤25 seconds
Recommended maintenance period 12 months
Conductivity (Optional) Range 1-2000uS/cm / 1~200mS/m
Accuracy ±1.5%FS
Repeatability ≤0.5%FS
Response time ≤30 seconds
Recommended maintenance period 3-6 months
Dissolved oxygen (Optional) Range 0-20mg/L
Accuracy ±0.3mg/L
Repeatability ≤±1.5%
Response time ≤30 seconds
Recommended maintenance period 1-3 months
Expansion port Port type RS485、4-20mA、0-5V

 

  • Introduction

The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.


Product detail pictures:

Buy Ph Controler Suppliers –  Sinomeasure Multi-parameter analyzer – Sinomeasure detail pictures

Buy Ph Controler Suppliers –  Sinomeasure Multi-parameter analyzer – Sinomeasure detail pictures

Buy Ph Controler Suppliers –  Sinomeasure Multi-parameter analyzer – Sinomeasure detail pictures


Related Product Guide:

It is a good way to improve our products and service. Our mission is to develop creative products to customers with a good experience for Buy Ph Controler Suppliers – Sinomeasure Multi-parameter analyzer – Sinomeasure , The product will supply to all over the world, such as: kazakhstan, Ecuador, Swaziland, We have our own registered brand and our company is developing rapidly owing to high quality products, competitive price and excellent service. We sincerely hope to establish business relations with more friends from home and abroad in the near future. We look forward to your correspondence.
  • Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Julie from Jeddah - 2017.12.09 14:01
    This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Daisy from Austria - 2017.12.02 14:11